- Capacity
- 1,024 Wh
- Continuous output
- 1,800 W
- Battery type
- LiFePO4
- Expandable
- To 5,000 Wh
- 240V
- No
- Weight
- 27.6 lb
Compare home backup power stations
Estimate how much battery your outage plan needs, then filter large, expandable power stations by the numbers that matter for a house: capacity, continuous output, start-up surge and 240V.
Specs from manufacturer pages, checked Nov 2026. No prices, ratings or test claims.
2. Read the table in this order
- Continuous output (W) must cover everything that runs at the same time. Too low and the unit shuts off, however big the battery.
- Start-up surge (W) matters for motors: sump and well pumps, fridge compressors, furnace blowers. Check it on the model page.
- Capacity (Wh) sets how many hours you get. If one battery is short, check whether the model takes the maker’s expansion batteries.
- 240V is only needed for 240V appliances. Most fridges, furnace blowers and sump pumps run on 120V.
Plug-in use is simple. Powering house circuits needs a transfer switch or interlock installed by a licensed electrician.
All 17 models, side by side
Sorted by battery capacity. Tap a model for every spec with its source link.
- Capacity
- 2,048 Wh
- Continuous output
- 2,400 W
- Battery type
- LiFePO4
- Expandable
- To 4,096 Wh
- 240V
- No
- Weight
- 41.7 lb
- Capacity
- 2,048 Wh
- Continuous output
- 2,400 W
- Battery type
- LiFePO4
- Expandable
- Yes
- 240V
- No
- Weight
- 45 lb
- Capacity
- 2,073.6 Wh
- Continuous output
- 2,600 W
- Battery type
- LiFePO4
- Expandable
- No
- 240V
- No
- Weight
- 53.35 lb
- Capacity
- 2,764.8 Wh
- Continuous output
- 3,840 W
- Battery type
- LiFePO4
- Expandable
- To 19,354 Wh
- 240V
- Yes
- Weight
- 83.78 lb
- Capacity
- 3,072 Wh
- Continuous output
- 3,600 W
- Battery type
- LiFePO4
- Expandable
- To 12,288 Wh
- 240V
- Linked
- Weight
- 91.5 lb
- Capacity
- 3,072 Wh
- Continuous output
- 3,600 W
- Battery type
- LiFePO4
- Expandable
- No
- 240V
- No
- Weight
- 59.52 lb
- Capacity
- 3,072 Wh
- Continuous output
- 3,600 W
- Battery type
- LiFePO4
- Expandable
- To 15,360 Wh
- 240V
- No
- Weight
- 83.3 lb
- Capacity
- 3,072 Wh
- Continuous output
- 3,600 W
- Battery type
- LiFePO4
- Expandable
- Yes
- 240V
- Linked
- Weight
- 79 lb
- Capacity
- 3,072 Wh
- Continuous output
- 3,600 W
- Battery type
- LiFePO4
- Expandable
- Yes
- 240V
- No
- Weight
- 63.3 lb
- Capacity
- 3,600 Wh
- Continuous output
- 3,600 W
- Battery type
- LiFePO4
- Expandable
- To 10,800 Wh
- 240V
- Linked
- Weight
- 99 lb
- Capacity
- 3,840 Wh
- Continuous output
- 6,000 W
- Battery type
- LiFePO4
- Expandable
- To 26,880 Wh
- 240V
- Yes
- Weight
- 136.7 lb
- Capacity
- 3,993.6 Wh
- Continuous output
- 3,600 W
- Battery type
- LiFePO4
- Expandable
- To 20,000 Wh
- 240V
- Linked
- Weight
- 115.74 lb
- Capacity
- 4,096 Wh
- Continuous output
- 4,000 W
- Battery type
- LiFePO4
- Expandable
- Yes
- 240V
- Yes
- Weight
- 113.54 lb
- Capacity
- 5,040 Wh
- Continuous output
- 7,200 W
- Battery type
- LiFePO4
- Expandable
- Yes
- 240V
- Yes
- Weight
- 134.5 lb
- Capacity
- 5,120 Wh
- Continuous output
- 7,200 W
- Battery type
- LiFePO4
- Expandable
- To 35,800 Wh
- 240V
- Yes
- Weight
- 123.9 lb
- Capacity
- 6,144 Wh
- Continuous output
- 7,200 W
- Battery type
- LiFePO4
- Expandable
- To 30,720 Wh
- 240V
- Yes
- Weight
- —
Specs from manufacturer pages, checked Nov 2026. Each model page links the source of every value. “Linked” 240V means 240V only by pairing two units or with the brand’s hub, not from one unit alone.
No model in our list matches every filter. Clear a filter, or see how expansion batteries and two linked units change the picture on each model page.
Shortlists by spec
Sorted straight from the manufacturer numbers in the table. Not ratings.
Most expandable
Largest total with the maker’s own expansion batteries (one unit).
- Pecron F5000LFP · 35,800 Wh max
- EcoFlow DELTA Pro Ultra · 30,720 Wh max
- Anker SOLIX F3800 Plus · 26,880 Wh max
Highest continuous output
For several large loads at once.
- Jackery Explorer 5000 Plus · 7,200 W
- Pecron F5000LFP · 7,200 W
- EcoFlow DELTA Pro Ultra · 7,200 W
240V from one unit
Needed for 240V appliances such as some well pumps (through a transfer switch).
- BLUETTI Apex 300 · 2,764.8 Wh
- Anker SOLIX F3800 Plus · 3,840 Wh
- EcoFlow DELTA Pro 3 · 4,096 Wh
- Jackery Explorer 5000 Plus · 5,040 Wh
Fastest listed UPS switchover
As stated by the maker; not every model claims a figure.
- BLUETTI Apex 300 · 0 ms
- Pecron F5000LFP · 0 ms
- EcoFlow DELTA Pro Ultra · 0 ms
How to choose a power station for home backup
A home backup power station is a large battery with a built-in inverter, so it can run ordinary 120V appliances when the grid goes down. Unlike a gas generator it makes no exhaust, so most makers allow indoor use (follow your model’s manual). The trade-off is energy: a battery holds a fixed number of watt-hours, so the right size depends on what you run and for how long.
Start with your loads, not the box
List what must keep running: usually the refrigerator, a furnace blower in winter, a sump pump in wet seasons, Wi-Fi, phones and a few lights. The home backup sizing calculator adds their watts, how often each one actually runs, and the outage length, then allows for inverter losses. Its result is the capacity to look for; the running and start-up watts are the output to look for.
Capacity (Wh) vs output (W)
Watt-hours are the size of the fuel tank; watts are how fast you can draw from it. A 3,000 Wh battery running a 300 W average load lasts roughly 3,000 × 0.85 ÷ 300 ≈ 8.5 hours (the 0.85 covers inverter losses; see the runtime calculator). A unit with a big battery but low continuous output still cannot start a large well pump.
Expansion batteries and linked units
Many home backup models accept the same brand’s extra battery packs, which is the cheapest way to add hours without buying a second inverter. Some brands also link two units for more output or for 240V. The table’s “Expandable” column shows each maker’s listed maximum for one unit.
Battery chemistry
Most current home backup units use LiFePO4 (lithium iron phosphate) cells, which makers typically rate for thousands of charge cycles. Some older or lighter units use NMC cells. Each model page lists the cycle rating the maker publishes, word for word in its source.
UPS / EPS switchover
Some units switch from wall power to battery automatically within a stated number of milliseconds, which keeps a router or a desktop computer running through a blackout. Makers measure this differently, so treat it as the maker’s claim. For medical equipment, ask the device provider what backup it needs; we only list power draw.
Connecting to your home
Running appliances from the unit’s own outlets with appropriately rated cords is the simple option. Feeding house circuits requires a transfer switch or interlock kit installed by a licensed electrician to your local code and the maker’s instructions. Never plug a power station into a wall outlet to “backfeed” the house: it can energize the utility line and endanger line workers.
Where the numbers come from
Every spec in this table is copied from the manufacturer’s own product page, spec sheet or manual, with the source link and check date kept for each value. We do not test units, give ratings or show prices (they change too often; the buttons open the brand’s store, where the current price is shown). Read how we compare or report an error on the corrections page.