Home backup sizing calculator

Tick what you want to keep running, adjust watts and how often each appliance runs, and set the outage length. You get the battery size to look for and the output a power station must handle.

Appliances to keep running
24 hours
Percent of stored energy that reaches AC appliances. 85% is our default; see the method below.
Estimated energy need:About — Wh
Average draw
—
Running watts (all on at once)
—
Start-up watts to plan for
—
240V needed?
No
See power stations that fit

How the estimate works

  1. Average watts = running watts × quantity × the share of time each appliance actually draws power. A fridge compressor cycles on and off; a router runs all the time.
  2. Energy = average watts × outage hours.
  3. Battery size = energy ÷ inverter efficiency, rounded up to the next 100 Wh. Turning stored DC power into 120V AC loses some energy; we plan with 85% and you can change it above.
  4. Running watts = everything ticked switched on at once: the power station’s continuous output should be at least this.
  5. Start-up watts = running watts plus the largest single start-up surge (motors draw extra for a moment when they start). Compare it with the power station’s surge or peak rating.

These are planning estimates. Real appliances vary by model, age and temperature. For the most accurate result, use the watts printed on each appliance’s label or manual, or measure with a plug-in energy meter. Many power stations also show live watts on their display.

Medical equipment

We do not suggest a wattage for medical devices. Enter the figure on your own device’s label or manual, and ask your equipment provider or doctor what backup arrangement they recommend.

Things a battery is not good at

Electric water heaters, ranges, dryers and central air conditioners draw thousands of watts for long periods. They are usually left out of a portable battery backup plan; a gas furnace’s blower fan, by contrast, is a common and practical load.

From the estimate to a model

“See power stations that fit” opens the comparison table filtered to your numbers: models whose own battery covers it, models that need the maker’s expansion battery, and models whose output is too low.

Preset wattages and their sources

Typical figures, used only as starting values. Your appliance’s label wins.

ApplianceRunning WStart-up WRuns % of timeSource
Refrigerator22567533%US DOE Energy Saver appliance calculator · Runs about 1/3 of the time (VT/DOE: divide plugged-in time by three); start-up = 3× running (VT motor rule)
Furnace blower29588550%US DOE Energy Saver appliance calculator · Gas furnace fan only; 50% of the time is our assumption (it runs while heating); start-up = 3× running
Sump pump5981,79420%Liberty Pumps 250 series (1/3 hp) spec sheet: 5.2 A at 115 V · 5.2 A × 115 V; 20% is our assumption (depends on how fast the pit fills); start-up = 3× running
Wi-Fi router20—100%Penn State EGEE 102, Common Appliance Power Ratings · Upper end of 5–20 W; runs all the time
LED lights9—100%US FTC, Shopping for Light Bulbs · 9 W each (60 W-equivalent LED); 4 bulbs by default
Medical deviceYour label—100%Your device label · No preset: enter the watts on your device label or manual, and ask your provider about backup needs
Chest freezer25—100%ENERGY STAR, Freezers · Average draw from about 215 kWh per year for an ENERGY STAR chest freezer (215,000 Wh ÷ 8,760 h)
Well pump (deep well)7252,17510%US DOE Energy Saver appliance calculator · VT range 250–1,100 W; 10% is our assumption; many deep-well pumps are 240V: check the label
TV60—100%Penn State EGEE 102, Common Appliance Power Ratings · Upper end of 40–60 W for a 36-inch flat screen
Laptop50—100%Virginia Cooperative Extension / DOE, Estimating Appliance and Home Electronic Energy Use
Phone charging7.5—100%Lawrence Berkeley National Laboratory, Standby Power Summary Table (archived) · Highest measured while charging (average 3.68 W); 2 phones by default
Microwave1,100—5%Virginia Cooperative Extension / DOE, Estimating Appliance and Home Electronic Energy Use · Upper end of 750–1,100 W; 5% (3 minutes an hour) is our assumption
Coffee maker1,200—5%Virginia Cooperative Extension / DOE, Estimating Appliance and Home Electronic Energy Use · Upper end of 900–1,200 W; 5% is our assumption
Space heater1,500—50%Virginia Cooperative Extension / DOE, Estimating Appliance and Home Electronic Energy Use · Upper end of 750–1,500 W; 50% is our assumption. Drains a battery fast
Window air conditioner6001,80050%Penn State EGEE 102, Air Conditioner Efficiency · 6,000 BTU/h at EER 10 = 600 W (watts = BTU/h ÷ EER); 50% is our assumption; start-up = 3× running

Sources: US DOE Energy Saver appliance calculator; Liberty Pumps 250 series (1/3 hp) spec sheet: 5.2 A at 115 V; Penn State EGEE 102, Common Appliance Power Ratings; US FTC, Shopping for Light Bulbs; ENERGY STAR, Freezers; Virginia Cooperative Extension / DOE, Estimating Appliance and Home Electronic Energy Use; Lawrence Berkeley National Laboratory, Standby Power Summary Table (archived); Penn State EGEE 102, Air Conditioner Efficiency.